Temperature shock test chamber TS 120/3


Test procedure evaluation / documentation and integration of customer measurement data ensure a higher level of quality. TS120/3 temperature shock test chamber

Temperature shock test chamber TS120-3

TS 120/3 with three chambers
The TS 120/3 an innovative three-chamber system has been developed for demanding screening processes, which require more than two temperature chambers. All test zones may be operated as individual systems. The middle zone allows the preconditioning and post conditioning of specimens. Contactless sensors ensure exact limit positions and guarantee perfect tightness between the individual zones and thus very low energy consumption.

The TS 120/3 is equipped with an 8" colour touch panel (800 x 600 px).

TS 120/3 consists of three independently controlled chambers (one is the hot, one is the room temperature and the final one is the cold chamber). The three chambers are located on top of each other. The hot/cold temperature shock is invoked by quickly transferring the test specimens from one chamber to the other by means of an elevator. It exposes test specimens to shocking temperature change.

Application
Environmental conditions have a significant impact on the operability and reliability of electronic components, devices and equipment. Test procedures for regular applications are set forth in international standards and test specifications. The ESS test procedure allows for manufacturing faults detection at early stages of the production. Executing a couple of hundreds/thousands of temperature cycles allows for the prediction of the expected life span of test specimens.

Features

  • Test space: 120 l
  • Vertical order of the chamber for safe and quick test performance
  • Regular temperature distribution in test space via a high recirculating rate with optimum air flow
  • Hot chamber temperatures of +50°C to +220°C
  • Cold chamber temperatures of -80°C to +70°C
  • Alternating time between the chambers
  • More than 1,000 cycles are possible without defrosting via
  • A standard integrated volume compensation system for continuously operation
  • Low sound-pressure level, only 58dB(A)
  • Design Maintenance friendly positioning of the machine components
  • Entry port Ø80mm
  • Loading capacity of the lift 50kg
  • 8" TFT-colour touch screen display
  • Controlpad
  • Ready to plug-in